A Vance company - serving Alpharetta, GA

Before & After Gallery - Vance Gate Repair Alpharetta

Every visit starts with

Free on-site gate assessment - hinges, posts, and your LiftMaster or Nice gate operator checked before anything is quoted

The assessment is free and the quote is the invoice.

Styles & brands we work with

Wrought iron
Wrought iron
Wood & steel frame
Wood & steel frame
Farm & ranch
Farm & ranch
Sliding driveway gates
Sliding driveway gates
LiftMaster operators
LiftMaster operators

Before & after – our own jobs

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

Gate Repair Before & After in Alpharetta, GA

Photos don’t exaggerate. A gate that won’t close, a motor that groans, a hinge that’s pulled away from the brick column - these problems are visible, and so are the fixes. We’ve documented every job we’ve done in Alpharetta since 2014 because we want you to see what actually changes when a trained technician shows up with the right parts and a written plan. Below are representative jobs from the last few years. When we have your photos, they’ll sit right here too.

Call (678) 679-2152

Recent Transformations

Sagging Wrought-Iron Driveway Gate, Alpharetta - Hinge Rebuild & Post Stabilization

Wrought-iron driveway gate sagging at the hinge with visible gap between gate frame and brick column
Before: Hinge failure on a residential driveway gate in Alpharetta
Wrought-iron gate properly aligned with rebuilt hinge and stabilized brick column
After: Rebuilt hinge assembly with post stabilization

The gate had dropped two inches on the brick-column side. The original builder had used a single light-duty hinge with a 3/8-inch lag into soft mortar. We opened the column, set a steel post sleeve in hydraulic cement, and hung the gate on a dual-bearing adjustable hinge rated for 800 pounds. Under Clause 4, we photographed the mortar cure, the hinge torque setting, and the final reveal gap. The gate swings one-finger light now.

FAAC 746 Swing-Gate Motor Failure, Alpharetta - Control Board & Limit Switch Reset

FAAC 746 swing-gate operator with control housing open showing damaged wiring
Before: FAAC operator with intermittent open/close failure
FAAC 746 operator with organized wiring, new control board, and documented limit switch position
After: Rebuilt control system with documented limit settings

The FAAC 746 would open halfway in cold weather and stop. We traced it to a cracked solder joint on the control board and a limit switch set 12 degrees past mechanical travel. We installed a replacement FAAC control board, reset both limit cams to true mechanical stop minus 3 degrees, and labeled the wiring with the same diagram habit Adrian Vance developed on commercial access-control sites. The photo log shows before-and-after cam positions. No replacement motor needed - the existing 746 runs like it was new.

Aluminum Slide Gate Off Track, Alpharetta - Roller Replacement & Track Realignment

Aluminum slide gate derailed with visible roller damage and bent track section
Before: Slide gate derailed after a landscaping truck backed into the track
Aluminum slide gate on realigned track with new rollers and proper clearance
After: Rebuilt roller truck and realigned V-track

A landscaping crew had clipped the track end with a trailer hitch. The gate had jumped track and the owner had been opening it by hand for two weeks. We cut out the bent 12-foot track section, set a new piece with proper expansion gap for Alpharetta’s summer temperature swing, and replaced all four rollers on the truck assembly. The V-track was shimmed to 1/2-inch consistent clearance. We left the owner with photos of the weld, the roller part numbers, and the gap measurement at three points.

LiftMaster LA500 Gate Opener Installation, Alpharetta - Post-Mount Conversion

Older Mighty Mule gate opener with corroded arm and failed battery backup
Before: Failed Mighty Mule opener with corroded actuator arm
New LiftMaster LA500 gate operator with articulated arm and battery backup enclosure
After: LiftMaster LA500 with articulated arm and documented force settings

The existing Mighty Mule had a seized actuator and a battery tray that had leaked acid through the control housing. We discussed options - repair versus replace - and the owner chose a LiftMaster LA500 for the onboard battery backup and the MyQ integration. We fabricated a post-mount bracket to clear the existing stone pillar cap, set the force limit to 22 pounds per UL 325, and programmed the auto-close at 45 seconds. The photo record shows the force gauge reading, the wiring landing, and the final arm geometry at full open.

Broken Weld on Custom Steel Gate, Alpharetta - Field Repair & Reinforcement

Custom steel gate with cracked weld at frame corner and rust penetration
Before: Cracked frame weld with rust at the stress point
Reinforced steel gate corner with new weld, gusset plate, and rust-inhibiting primer
After: Welded repair with gusset reinforcement and protective finish

This was a 14-foot custom steel gate that had cracked at the lower frame corner where the picket load transferred to the hinge post. The original weld had no gusset and had been carrying sheer stress for eight years. We ground out the crack, welded a 3/16-inch gusset plate across the inside corner, and hit it with rust-inhibiting primer. The gate didn’t come off the property. The owner got photos of the penetration on the root pass and the finished gusset. Under the 365-Day Done Right Promise, if that weld cracks in the next year, we fix it at no charge.

Photo-Eye Misalignment on Dual Swing Gates, Alpharetta - Safety System Realignment

Misaligned photo-eye sensors on dual swing gate with visible offset between transmitter and receiver
Before: Photo-eye (the infrared beam that stops the gate if something crosses the path) misaligned by roughly two inches
Properly aligned photo-eye pair with documented beam height and obstruction test result
After: Realigned and tested safety beam with documented height and test record

The gate would reverse randomly during close cycle. We found the photo-eye receiver had been bumped by a trash can and was aimed at the transmitter’s mounting bracket instead of the lens. We realigned both units to 18 inches above grade per the install manual, cleaned the lenses with optical wipes, and ran the UL 325 obstruction test - a 6-inch diameter cylinder at mid-gate. The photo log shows the beam path, the test object in place, and the control board LED confirming clean signal. The gate hasn’t reversed once since.

Want Results Like These?

Repair technician patching a crack on an ornamental black metal gate post
Want Results Like These?

Every job above started the same way: a phone call to (678) 679-2152, answered by a live person. We schedule a free inspection, deliver a written price before any work begins under Haven Standard Clause 1, and leave you with a documented photo record under Clause 4. If you’re in Alpharetta and your gate isn’t doing what it should, call us. We’ll show you what’s wrong, fix it right, and prove it happened.

Written by Adrian Vance, Owner at Vance Gate Repair Alpharetta, serving Alpharetta since 2014.

Need Gate Repair help in Alpharetta? Licensed & insured · same-day response · free estimates
Call (678) 679-2152
Local Service Coverage

Request a Free Estimate in Alpharetta

Tell us what you need - Vance Gate Repair Alpharetta responds fast. No obligation.

By reaching out through this form, you agree to our Privacy Policy and agree that you may be contacted via phone, email, or SMS about your request, including by the independent professionals who may fulfill it.

Prefer to text? Text Us
Call Now - 24/7 Dispatch